MIL-W-52125B
3.23 Tiedown attachments. Each unit and each sectionalized component shall be provided with the integral attachments to permit tiedown of the unit or section to the floor or deck of the transportation medium (see 3.17.2 and 3.17.3). The tiedown attachments shall withstand dynamic thrusts encountered during transport, and static loads of 8G-forward, 8G-rearward,
2-1/2G-upward, and 1-1/2G-sideward where G equals the maximum shipping weight of the unit
or each sectionalized component. Attachments shall be rounded and beveled to prevent cutting of the tiedown material. Tiedown attachments may also be used as lifting attachments when such attachments meet requirements specified in 3.22.
3.24 Identification marking. The unit shall be identified in accordance with MIL-STD-130. The marking shall be applied to the unit on plates conforming to MIL-P-514, type I, style 1, composition C, of type 1, grade A, class 1 material. Plates shall be attached by screws, bolts, or rivets in a conspicuous protected location.
3.24.1 Shipping data plate. Shipping data plate shall conform to MIL-P-514, type III, composition C, of type I, grade A, class 1 material and in addition, shall show the silhouette of the unit in transport position indicating the center of gravity and the location and capacity of the lifting and the tiedown attachments. The plates shall be attached by screws, bolts, or rivets in a conspicuous protected location.
3.24.2 Instruction plates. Instruction plates shall be furnished and shall conform to
MIL-P-514, type III, composition C, of type I, grade A, class 1 material, dimensions to suit the application. These plates shall indicate sequence for start up, shut down, and normal operation; production capacity; and all inherent dangers which can stem from unsafe operation or an unsafe operating position. The safety, warning, caution, and notice plates shall be in accordance with USA Standard Z 35.1, except that the size may be reduced to be compatible with the available space. All plates shall be securely attached to the unit with machine screws, bolts, and nuts, or rivets, and shall be furnished and mounted by the supplier.
3.24.2.1 Warning plates. The following warning plates shall be furnished:
(a) A plate placed on the outside of the distribution panel (see 3.8.2.4), near main power inlet with the following wording:
"Warning. Install ground rod and lead by bolting ground wire to grounding stud on the unit frame before this unit is operated. A ground rod and lead
should also be installed at power source (generator)."
(b) A plate placed adjacent to grounding stud or bolt (3.8.3.1) with the following
wording:
"Attach ground wire here."
34
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business