MIL-W-52125B
19 July 1968
SUPERSEDING
MIL-W-52125A(MO)
29 July 1964
MILITARY SPECIFICATION
WASHING AND SCREENING UNIT, AGGREGATE, ELECTRIC-MOTOR-DRIVEN,
75-TON-PER-HOUR CAPACITY
This specification is mandatory for use by all Departments and Agencies of the
Department of Defense.
1. SCOPE
1.1 This specification covers a semitrailer-mounted, pneumatic-tired, electric-motor-driven aggregate washing and screening unit with dolly.
2. APPLICABLE DOCUMENTS
2.1 The following documents of the issue in effect on date of invitation for bids or request for proposal form a part of this specification to the extent specified herein:
SPECIFICATIONS Federal
W-C-586 - Conduit Outlets and Entrance Caps, Electrical; Cast Metal - for Shore Use.
FF-B-171 - Bearings, Ball, Annular (General Purpose).
FF-B-185 - Bearings, Roller, Cylindrical; and Bearings, Roller, Self-Aligning.
FF-B-187 - Bearing, Roller, Tapered. QQ-S-781 - Steel, Strapping, Flat.
QQ-S-790 - Steel, Strapping, Round (Bare and Zinc-Coated).
SS-R-406 - Road and Paving Materials; Methods of Sampling and
Testing.
TT-P-664 - Primer Coating, Synthetic, Rust-Inhibiting,
Lacquer-Resisting.
FSC 3820
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.